- Max10: ADC no longer working with .pof file
- Mark Material as the This new
- Draw Situation once the Realize
- Float this subject to possess Latest Associate
We think you may have that (or even more) slightly sluggish otherwise around ranked offers
I’m already dealing with Max10M16DAF256 and i struggle with the fresh ADC. sof document it works okay. pof file new ADC does not work any further, we.elizabeth ADC information is usually no, as someone else elements really works truthfully.
While using
You will find along with seen whenever coding with .pof document whilst still being allow suppy current with the, this new ADC functions. But after reset the production current (turn off and on once again), it generally does not performs any longer.
Should your second then you need to verify take a look at how you discharge the fresh new ADC Ip from reset. Hold it inside reset ‘a little longer’ following increase. Disappointed this may voice a tiny vague. That it is apparently a routine point into forum one cannot seem to have acquired an obvious, credible service.
Should this be the board then you need to check on the above mentioned and ensure this new rails rise monotonically. There aren’t any sequencing requirements however, if the do not rise correctly – perhaps not conference brand new Tramp time – the device have a tendency to misbehave. Reference ‘Figure 3. Tracked Stamina Offers Ramp Up’ from the ‘ electricity administration representative publication (
I additionally discover an identical issue with Max10 ADC an additional thread, but like you said there’s no provider for this.
The latest board is our notice structure panel. The issue is a large number of the boards are working fine with ” .pof “-document, and lots of of them beautiful girl Xuzhou get this ADC condition. Into the chatrooms having ADC situation, i examined throughout the resources of these boards regrettably we didn’t find any issue to the equipment. Such as for example in the list above, brand new chat rooms will work that have ” .sof ” as well as ” .pof “-document when the have voltage is obviously to the. After the also provide current was reset, the newest ADC does not any longer performs once the other individuals remains operating truthfully.
This makes me personally believe a whole lot more this problem can be power associated. You are demonstrably on the side of long lasting issue is offered you have working boards.
Can you bring a non performing board, disconnect the power supplies and electricity it out-of table provides? My personal concern is one an around ranked train isn’t up to supplying the inrush necessary and you can dips causing the POR circuitry an effective disease, and this (perhaps) actually documented.
You happen to be best. I did certain investigation regarding strength offers for Max10, therefore appears to be the analogue supply takes a little long up until it are at complete voltage peak (we have been playing with Max10 dual have unit, and that need several digital supplies and you will 1 analog also provide).
As with Max10 Electricity government member publication, it appears as though precisely the last power to own Max10 matter (attached photo), so we made an effort to swtich to your analog also provide very first and you may expect it to reach maximum level, right after which turn on others two digital provides, and that take only few hundred or so s to arrive maximum height. This will help to the fresh new maybe not-doing work ADC to be performing sporatically (not at all times doing work).
Nevertheless when i take a functional board (ADC usually functions) and you may do the contrary succession (i.elizabeth assist several digital provides on the earliest, then analogue likewise have), new ADC continues to be performing (i expected that it must not performs any more).
So somehow new ADC state relates to the benefit supply succession while the ramp duration of electricity offers, however, a clear cause for this condition might have been perhaps not located but really.